Solutions

Vacuum Wireless Profiler

The Vacuum Wireless Profiler is an industrial-grade temperature measurement system designed for vacuum furnaces and high-temperature manufacturing processes. It supports multi-channel temperature collection, wireless data transmission, breakpoint resume, and high-precision thermal analysis. The system helps manufacturers monitor temperature changes, verify process conditions, optimize thermal profiles, and improve quality control while reducing manual testing effort.

Field

Details

Product Name

Vacuum Wireless Profiler

Category

Digital Manufacturing & Process Solutions → Offline Temperature Measurement Products

Product Overview

Wireless temperature profiling system for vacuum furnaces and high-temperature processes.

Key Features

Multi-channel temperature monitoring, wireless data transmission, breakpoint resume, real-time curve monitoring, intelligent curve optimization, virtual curve simulation, standard process analysis, SPC analysis, and report generation.

Applications

Vacuum furnace monitoring, reflow and soldering process analysis, thermal profile collection, process calibration, and quality verification.

Key Benefits

Accurate temperature measurement, improved process visibility, reduced testing time, better process control, and reduced risk of rework.

Available Types

Iprofile Vacuum model; customization and alternative configurations to be confirmed with VCAM.

Performance Characteristics

High-precision temperature collection, multi-location measurement, repeatable testing, and reliable operation in demanding environments.

Industries Served

Electronics Manufacturing, EMS, Automotive Electronics, Aerospace & Defense, and Industrial Manufacturing.

Handling & Maintenance

Inspect probes and insulation components regularly, protect the profiler from unsuitable operating conditions, and follow VCAM maintenance and calibration instructions.

Customization Options

Measurement-channel configuration, probe selection, insulation arrangement, reporting requirements, and process-integration options to be confirmed with VCAM.

Technical Specifications

Parameter

Specification

Model

Iprofile Vacuum

Number of Channels

8

Profiler Size

L146 × W61 × H19 mm

Insulation Box Size

L345 × W114 × H35 mm

Probe Type

K-Type

Acquisition Rate

0.1–30 seconds

Data Transfer

USB

Continuous Testing

Multiple tests; stores up to 30 data records

Startup Method

Button start, delay start, temperature start

Instrument Temperature Resistance

0–85°C

Operating Voltage

DC 5V 1A

Instrument Accuracy

±0.5°C

Resolution

0.1°C

Measuring Range

0–750°C

Stop Method

Button stop, temperature stop

Memory Capacity

86,400 points

Insulation Box Material

Stainless steel insulation sleeve

Operating System